Daikin AC Error U4

Daikin AC Error Code U4 | Signal Transmission Error | Atlas Aircon
Communication Failure

Daikin Error U4

Signal Transmission Error.
The Indoor & Outdoor Units have stopped talking.

Common Cause

Loose Wiring (1-2-3)

Check

Power Supply

Diagnosis

PCB Handshake

The “Lost Connection” Problem

The U4 Error is the most common fault in Daikin Inverter ACs. Inverter technology relies on constant data exchange between the IDU (Indoor Unit) and ODU (Outdoor Unit) via the signal wire (usually Terminal 3).

The Logic: If the Indoor PCB sends a command (“Start Compressor at 50% speed”) and doesn’t get a “Roger that” reply from the Outdoor PCB within a few seconds, it triggers U4 and shuts down the system.

1 DIY Checks (Before Calling Us)

The 5-Minute Reset

Turn off your main MCB switch. Wait for 5 full minutes. Turn it back on. This resets the communication logic and often clears temporary glitches.

Check Terminal Block

If you can safely access the outdoor unit, check the wires marked 1, 2, and 3. Are they loose? Burnt? Loose neutral wires are a prime suspect.

Rat Bite on Cable

Look at the thick cable running from your indoor unit to the outdoor unit. If rats have chewed the signal wire, U4 is inevitable.

Atlas Aircon Repair Protocol

How we fix the U4 Fault:

  1. 01.
    Continuity Test We use a multimeter to check the 3-core communication wire. If there is a break in the middle, we replace the entire cable (no joints allowed).
  2. 02.
    PCB Fuse Check Outdoor PCBs have glass fuses. Voltage fluctuations often blow these fuses, killing the outdoor unit’s brain. Replacing the fuse restores power.
  3. 03.
    Communication Circuit Repair If wires and fuses are fine, the Optocoupler or Comms IC on the PCB is damaged. We perform component-level repair or replace the PCB.

Estimated Repair Cost (Atlas Aircon)

Wiring/Fuse Fix: ₹500 – ₹950
PCB Repair/Replace: ₹2,800+

Frequently Asked Questions

Why does U4 happen after a power cut?
Sudden power surges when electricity returns can confuse the PCB’s synchronization or blow the protective fuse on the outdoor unit. A simple reset often fixes synchronization, but a blown fuse needs a technician.
Can I joint the wire if rats cut it?
We strongly advise against it. Inverter communication signals are sensitive. Joints/tape can create resistance or noise (interference), causing the U4 error to return. Replacing the full wire is best.
Is U4 related to gas leakage?
No. U4 is strictly an electrical/communication fault. It has nothing to do with refrigerant levels (Gas). Low gas would show errors like U0 or F3.